I suspect something is wrong, but need confirmation. I have three
deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#2
|
|||
|
|||
Yes. The purpose of a combiner is to connect the starter battery
to the charger when it needs sharging. Either get rid of the combiner (recommended) or remove the charging connection from the charger to the starter battery. Doug s/v Callista "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#3
|
|||
|
|||
Doug, could you be more specific, why do you recommend getting rid of the
combiner? I would think the problem is that the charger takes its lead from the main bank which probably requires more charging than the starter and consequently the starter bank is being over charged. I know of combiners, isolators and echo chargers, but do not know which is the best. Without one of them, you need dual outputs from both the charger and alternator or you need a 1/2/both switch which is no longer the recommended approach. I use an echo charger and only connect the charger to the main bank and it works great. Don't slam me hear, I'm still trying to get a handle on best practices, and why, myself. John "Doug Dotson" wrote in message ... Yes. The purpose of a combiner is to connect the starter battery to the charger when it needs sharging. Either get rid of the combiner (recommended) or remove the charging connection from the charger to the starter battery. Doug s/v Callista "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#4
|
|||
|
|||
John's diagnosis is probably correct. And there is nothing wrong with a
battery combiner. It is far better than an isolater (no voltage drop) and just as effective as the Echo Charger. David "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#5
|
|||
|
|||
I would be a bit suspicious of the quality of the starting battery.
My experience has been that when batteries get on their last legs (and need to be changed anyway) that they seem to boil away the water a lot. It seems that no matter how you stay on top of keeping it filled it seems to boil away. I suspect that it may be due to sulfation buildup that creates something like an internal short, heat, and loss of water. Good luck Don "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#6
|
|||
|
|||
I don't like them. They don;t provide an optimal
charge for the start battery. A better solution is to get an Eliminator from AmplePower or an EchoCharge from Balmar. They provide a better charge for the starting battery. Depending upon your use, using the second tap on the charger is great if you get to shorepower regularly. If you are away from shorepower for extended periods then charging you house bank from the alternator with an Eliminator or EchoCharge is a better solution. The problem with your current setup is that the starting battery is being charged by both outputs of the shorepower charger. As such it cannot determine when to taper off the charge on just the starting battery. Doug s/v Callista "johnh" wrote in message news:YS18d.171507$D%.29911@attbi_s51... Doug, could you be more specific, why do you recommend getting rid of the combiner? I would think the problem is that the charger takes its lead from the main bank which probably requires more charging than the starter and consequently the starter bank is being over charged. I know of combiners, isolators and echo chargers, but do not know which is the best. Without one of them, you need dual outputs from both the charger and alternator or you need a 1/2/both switch which is no longer the recommended approach. I use an echo charger and only connect the charger to the main bank and it works great. Don't slam me hear, I'm still trying to get a handle on best practices, and why, myself. John "Doug Dotson" wrote in message ... Yes. The purpose of a combiner is to connect the starter battery to the charger when it needs sharging. Either get rid of the combiner (recommended) or remove the charging connection from the charger to the starter battery. Doug s/v Callista "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#7
|
|||
|
|||
"Doug Dotson" blabbered in message-id
the following folklore and rubbish....... This post is a perfect example of why one should not seek expert advice on usenet. It is full of idiots such as Doug who thinks he knows it all. I don't like them. They don;t provide an optimal charge for the start battery. A better solution is to get an Eliminator from AmplePower or an EchoCharge from Balmar. They provide a better charge for the starting battery. Depending upon your use, using the second tap on the charger is great if you get to shorepower regularly. If you are away from shorepower for extended periods then charging you house bank from the alternator with an Eliminator or EchoCharge is a better solution. The problem with your current setup is that the starting battery is being charged by both outputs of the shorepower charger. As such it cannot determine when to taper off the charge on just the starting battery. Doug s/v Callista 1. A start battery does not need an optimal charge. 2. If it did then you are correct in that the Eliminator from Amplepower would provide such a charge. That is the _only_ correct statement in your entire post. 3. The Echo Charge is made by Cruising Equipment (now part of Xantrex) not Balmar. 4. The echo charge does not provide an "optimal charge" for the engine battery. It simply copies the charge profile of its input subject to a 15 amp (7.5 amp for the 24 volt model) current limit. Therefore if the alternator output is at 14.4 volts, then so is the output of the Echo Charge. No matter how long it is on. There is therefore _no_ advantage over a battery combiner. 5. The Xantrex charger does have separate outputs but they are _not_ separately controlled and the charger does _not_ measure the voltage or current on each output separately so removing his battery combiner will make no difference whatsoever. The charger will already be holding both batteries at the same voltage. 6. Your statement that QUOTE "The problem with your current setup is that the starting battery is being charged by both outputs of the shorepower charger. As such it cannot determine when to taper off the charge on just the starting battery" /QUOTE....... is total garbage for the reasons given above. 7. Your statement QUOTE "Depending upon your use, using the second tap on the charger is great if you get to shorepower regularly" /QUOTE..... is no different than using the battery combiner he already has. Again for the reasons given above. Now to genuinely help the original poster. Don's explanation is almost certainly the correct one. The engine start battery is duff. Almost certainly sulphated up. The first major symptom of this is one shorted cell which then leaves the other 5 being overcharged and they lose water at a very fast rate. David also is correct. There is nothing wrong with a battery combiner. Now then Doug, I dare you to argue back. :-) |
#8
|
|||
|
|||
OK , I see your point. I have 2 choices. I can keep the combiner and
use only one tap from the charger. The result is a starting battery that is never optimally charged. Or I can lose the combiner, use both taps of the charger and get optimally charged battery banks, but have to deal with the inconvenience of manual switching. On Mon, 4 Oct 2004 17:19:29 -0400, "Doug Dotson" wrote: I don't like them. They don;t provide an optimal charge for the start battery. A better solution is to get an Eliminator from AmplePower or an EchoCharge from Balmar. They provide a better charge for the starting battery. Depending upon your use, using the second tap on the charger is great if you get to shorepower regularly. If you are away from shorepower for extended periods then charging you house bank from the alternator with an Eliminator or EchoCharge is a better solution. The problem with your current setup is that the starting battery is being charged by both outputs of the shorepower charger. As such it cannot determine when to taper off the charge on just the starting battery. Doug s/v Callista "johnh" wrote in message news:YS18d.171507$D%.29911@attbi_s51... Doug, could you be more specific, why do you recommend getting rid of the combiner? I would think the problem is that the charger takes its lead from the main bank which probably requires more charging than the starter and consequently the starter bank is being over charged. I know of combiners, isolators and echo chargers, but do not know which is the best. Without one of them, you need dual outputs from both the charger and alternator or you need a 1/2/both switch which is no longer the recommended approach. I use an echo charger and only connect the charger to the main bank and it works great. Don't slam me hear, I'm still trying to get a handle on best practices, and why, myself. John "Doug Dotson" wrote in message ... Yes. The purpose of a combiner is to connect the starter battery to the charger when it needs sharging. Either get rid of the combiner (recommended) or remove the charging connection from the charger to the starter battery. Doug s/v Callista "Marc" wrote in message ... I suspect something is wrong, but need confirmation. I have three deep cycle wet group 24's as the house bank and 1 deep cycle wet group 24 as the starting bank. A 150 amp combiner is installed between the banks and both banks are connected to individual legs of a xantrex 20 amp charger. The boat sits in a slip with shore power connected, charger on, and a reefer running 24/7 off the house bank. I am losing electrolyte faster in the starting bank than the house bank. Question : Since I have a combiner, should the charger be hooked up to both banks? Could this be causing the electrolyte loss? |
#9
|
|||
|
|||
"Doug Dotson" wrote in
: I don't like them. They don;t provide an optimal charge for the start battery. A better solution is to get an Eliminator from AmplePower or an EchoCharge from Balmar. They provide a better charge for the starting battery. What do you base this upon? -- Geoff |