Home |
Search |
Today's Posts |
#21
![]()
posted to rec.boats.electronics
|
|||
|
|||
![]() "Peter Albright" wrote in message news:u2fvg.14644$A8.3191@trnddc02... Glen, Have you considered biasing the voltage sense line, to adjust the regulator output voltage? I have been thinking about that. Looks like that would be the only way to control it. The internal regulator is set to maintain 14.4V on the sense line. Boosting the sense line 1.2V would bring the output down to a safe 13.2V float. You could actually put a microprocessor to sense the battery voltage and bias the alternator sense to do everything a "smart" regulator does but that would be more work than I have time for. -- Glenn Ashmore I'm building a 45' cutter in strip/composite. Watch my progress (or lack there of) at: http://www.rutuonline.com Shameless Commercial Division: http://www.spade-anchor-us.com |
#22
![]()
posted to rec.boats.electronics
|
|||
|
|||
![]()
Glenn Ashmore wrote:
"Paul Hovnanian P.E." wrote Actually, the alternator will put out whatever the battery and loads require. Unless you are charging a huge battery bank and/or have 200 A load connected to it, it won't put out that much. Given the electrical (and mechanical) losses, the input HP will be whatever are needed to provide the electrical output. The larger alternator will have lower electrical losses, but higher mechanical. All in all, this unit won't present a mechanical load significantly different than a smaller alternator. That's just it. There will definitely be a heavy load on it. When it cranks up every morning it will be seeing a 900AH battery bank ready to take the first 225 amps in bulk mode. This unit must be matched to the appropriate regulator. If you didn't get one with the alternator, the deal may not have been that good. It has the regulator built in. Pretty interesting one too. Even has a battery voltage sense connection. However the regulator does not have a way to change from bulk to absorption to float modes and there is no equalization. The shore power charger can handle the equalization and with my normal use pattern of 50% to 85% charge will rarely need float except at the dock but it would be nice to have optomized bulk and absorption ability. That could be a problem. If you could tweak the voltage setting down a bit, you could slow down the battery charge rate and the resulting engine load. Petes's suggestion is pretty good. Put in some current sensing on the gen. output and use that to bump the V sense line up as the generator output approaches a setting suitable to your prime mover. You'll need a gain control to set the V bias per amp load and set it so that the system remains stable. -- Paul Hovnanian ------------------------------------------------------------------ Have a pleasant Terran revolution. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|