Home |
Search |
Today's Posts |
#1
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
Hi,
Known: 50 amp shore power receptacle. 30 amp boat connection. 30 amp isolation transformer. 4kw generator connected to boatside 110v system. Battery chargers and 110v receptacles and 13v ac lighting fed from shore power/isolation transformer. Required: Converting this steel boat to live-aboard with occasional trips. Need to increase electrical system to run: 14amp convection oven, new 10 cu ft fridge and TV and stereo system. Solution: I know the simplest, and most EXPENSIVE, solution is to buy and install a 50 amp isolation transformer. BUT.. Could I install a second 30amp boat receptacle, connect it to shore power using a 50x30x30 'Y' power cord, run second 30amp wiring to new 50amp breaker thence to receptacles for oven, fridge and TV? This system would not be connected to generator nor to existing system nor to hull. Would this work? My concern is the 'Y' connector on the shore power cord. Any suggestions most welcome. David Morton |
#2
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
mortond wrote:
Hi, Known: 50 amp shore power receptacle. 30 amp boat connection. 30 amp isolation transformer. 4kw generator connected to boatside 110v system. Battery chargers and 110v receptacles and 13v ac lighting fed from shore power/isolation transformer. Required: Converting this steel boat to live-aboard with occasional trips. Need to increase electrical system to run: 14amp convection oven, new 10 cu ft fridge and TV and stereo system. Solution: I know the simplest, and most EXPENSIVE, solution is to buy and install a 50 amp isolation transformer. BUT.. Could I install a second 30amp boat receptacle, connect it to shore power using a 50x30x30 'Y' power cord, run second 30amp wiring to new 50amp breaker thence to receptacles for oven, fridge and TV? This system would not be connected to generator nor to existing system nor to hull. Would this work? My concern is the 'Y' connector on the shore power cord. Should be no problem at all. Each transformer's secondary will be fully isolated from a)shore power; and b)the other transformer's secondary. Probably the cheapest solution. Just follow ABYC AC wiring practices and you should be fine. Chuck Any suggestions most welcome. David Morton ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#3
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
On Wed, 22 Nov 2006 15:42:17 -0500, nospam wrote:
mortond wrote: Hi, Known: 50 amp shore power receptacle. 30 amp boat connection. 30 amp isolation transformer. 4kw generator connected to boatside 110v system. Battery chargers and 110v receptacles and 13v ac lighting fed from shore power/isolation transformer. Required: Converting this steel boat to live-aboard with occasional trips. Need to increase electrical system to run: 14amp convection oven, new 10 cu ft fridge and TV and stereo system. Solution: I know the simplest, and most EXPENSIVE, solution is to buy and install a 50 amp isolation transformer. BUT.. Could I install a second 30amp boat receptacle, connect it to shore power using a 50x30x30 'Y' power cord, run second 30amp wiring to new 50amp breaker thence to receptacles for oven, fridge and TV? This system would not be connected to generator nor to existing system nor to hull. Would this work? My concern is the 'Y' connector on the shore power cord. Should be no problem at all. Each transformer's secondary will be fully isolated from a)shore power; and b)the other transformer's secondary. Probably the cheapest solution. Just follow ABYC AC wiring practices and you should be fine. Chuck Reading the above I see no mention of a new additional 30A isolation transformer? Also it seems that you currently have a 30A connector (and probably 30A cabling) fed from a 50A supply, surely unnacceptable. Richard Nb "Pound Eater" Parkend G+S |
#4
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
Electricky Dicky wrote:
Reading the above I see no mention of a new additional 30A isolation transformer? Also it seems that you currently have a 30A connector (and probably 30A cabling) fed from a 50A supply, surely unnacceptable. Richard Nb "Pound Eater" Parkend G+S Agreed. Thanks for catching those, Richard. Chuck ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#5
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
OK, now that I'm awake, I'll try to be more lucid.
Although it is not exactly what you proposed, the simplest and best way to provide an additional 24 amps for the oven, fridge, etc., is to add a second 30A cable, breaker, isolation transformer, and associated wiring. The isolation transformer is especially appropriate for a steel vessel. The cost would be greater if you were to install a 50A isolation transformer and the benefits would be marginal in my opinion. Having two independent branch circuits offers some redundancy and doesn't require that you mess with your existing AC wiring. Connecting the two 30A cables through a Y to a 50A shore power receptacle would be OK since it is extremely unlikely that all of your electrical loads would ever be on at the same time. Even if they were, presumably the combined load would not exceed 54 amps, which, under a worst case, would trip the shore power 50A breaker. Virtually all residential branch circuits in the US are sized based on the assumption that all loads will not be present simultaneously. Of course, if you know the assumption is false for your boat, that would require a different approach. While you could combine the secondaries of the two isolation transformers and have a single large circuit, I would recommend that you keep the new wiring separate from the old. Needless to say, combining the output of the existing isolation transformer with a new, un-isolated 30A circuit would negate the benefits of the existing transformer. Richard's point about using a 30A cable with a 50A receptacle is troubling. If that is what you are doing, there is a real risk that the 30A cable could short, cause a fire, etc., without the 50A shore power breaker tripping! The Y connection would be much safer. Apologies for the false start. Chuck ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#6
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
On Thu, 23 Nov 2006 15:13:36 -0500, chuck wrote:
OK, now that I'm awake, I'll try to be more lucid. Snip Richard's point about using a 30A cable with a 50A receptacle is troubling. If that is what you are doing, there is a real risk that the 30A cable could short, cause a fire, etc., without the 50A shore power breaker tripping! The Y connection would be much safer. Apologies for the false start. Chuck My point was that the 30A connector and therefore probably 30A cable FROM the Y are protected by a 50A breaker. Just had a google and seen a Marinco AF1 which is I assume is the type of gizmo you are discussing. Recipe for disaster IMHO. Though probably thousands in the field (or shoreside). Unless each leg is fused? But that is not discussed on the site I saw. Richard Nb "Pound Eater" Parkend G+S |
#7
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
Electricky Dicky wrote:
My point was that the 30A connector and therefore probably 30A cable FROM the Y are protected by a 50A breaker. Just had a google and seen a Marinco AF1 which is I assume is the type of gizmo you are discussing. Recipe for disaster IMHO. Though probably thousands in the field (or shoreside). Unless each leg is fused? But that is not discussed on the site I saw. Richard I did misunderstand your point. Sorry. Seems I just can't get on the right wavelength in this thread. Certainly the NEC would not allow a 50A breaker to protect a 30A branch circuit. But using 30A cables on 50A receptacles is sort of like using an extension cord rated at 15 amps on a residential branch circuit protected with a 30A breaker. Not the smartest thing to do, but probably just as common as what happens with a lot of shore power connections at marinas. I guess UL rates residential extension cords and the NEC jurisdiction stops at the receptacle. There is some disagreement on whether the NEC stops at the marina's shore power pedestal but most seem to believe it does not. Legalities aside, the 10 ga. wire in typical marine-type 30A cords is not rated for 50A and really should not be connected to a 50A breaker. Chuck ----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==---- http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups ----= East and West-Coast Server Farms - Total Privacy via Encryption =---- |
#8
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
On Thu, 23 Nov 2006 22:28:27 -0500, chuck wrote:
Electricky Dicky wrote: My point was that the 30A connector and therefore probably 30A cable FROM the Y are protected by a 50A breaker. Just had a google and seen a Marinco AF1 which is I assume is the type of gizmo you are discussing. Recipe for disaster IMHO. Though probably thousands in the field (or shoreside). Unless each leg is fused? But that is not discussed on the site I saw. Richard I did misunderstand your point. Sorry. Seems I just can't get on the right wavelength in this thread. Go back to bed, have a snooze then try again ;-) Certainly the NEC would not allow a 50A breaker to protect a 30A branch circuit. But using 30A cables on 50A receptacles is sort of like using an extension cord rated at 15 amps on a residential branch circuit protected with a 30A breaker. Not the smartest thing to do, but probably just as common as what happens with a lot of shore power connections at marinas. One day the US will have a system as we have in the UK. All houshold plugs fitted with a fuse. Mind you it doesnt stop some people wiring the plug with 2A cable and fitting a 13A fuse ;-) I guess UL rates residential extension cords and the NEC jurisdiction stops at the receptacle. There is some disagreement on whether the NEC stops at the marina's shore power pedestal but most seem to believe it does not. Legalities aside, the 10 ga. wire in typical marine-type 30A cords is not rated for 50A and really should not be connected to a 50A breaker. Chuck Richard |
#9
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
Hi,
Sorry, I guess I wasn't as clear as I thought! The marina only has a 50 amp receptacle. I wanted to avoid the cost of buying a second 30 amp or a single 50 amp isolation transformer. Basically, I wnted to hook-up the convection oven and fridge to the 50 amp shore power receptacle, like an extension cord, except, the extension cord would be routed via a 30amp breaker on the boat (revised that from a 50 amp) to one leg of the 'Y' branch of the shore power cord. The appliance grounds would not be connected to the boat at all. I assume the shore power ground would be isolated from the boat by the existing isolation transformer on one leg of the "Y" and because there is no boat connection on the other "Y" leg. Thanks for the interest. David |
#10
posted to rec.boats.electronics
|
|||
|
|||
Adding-on to 110v shore power system.
Hi Chuck,
I also think the ring- main system with fused plugs is a better solution and easier, and cheaper, to install. To use that system in the US will not happen, to many vested interests to change. Thanks, David Morton |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
What does MIT say about ionization and lightning?? | ASA | |||
FS: Shore Power cord in NY | Marketplace | |||
FS: New Marinco 30A shore power cable in PA | Marketplace | |||
Shore Power | Cruising |