Michael A. Terrell wrote:
John Popelish wrote: Michael A. Terrell wrote: John Popelish wrote: What does this failure tell us about the PIV rating of the trio? Not much, I think. You don't know that thew trio failed from excessive voltage. Could have been a bond failure that overheated one of them. All three diodes were open. So what do you conclude caused this failure, if anything? I have no idea. All I found was four lugs and burnt plastic ash. There was nothing left to do failure analysis on. I would suspect an intermittent short between the rectifier output and ground. But, I guess, if a high enough voltage transient occurred, it could have shorted a rectifier and then that short blew the other two. Of a diode bond failed enough to overheat one die, causing the same cascade. But do you agree with my analysis of the normal voltage applied to these diodes? You clipped it without comment. |