Home |
Search |
Today's Posts |
#122
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite"
wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year. It was brand new, still in the box and she decided to have a whole house generator installed instead. She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300. It's rated at 4,750 peak watts and 3800 watts continuous. Engine is 6.3 hp. I put it together last spring and fired it up. Ran fine, was not overly noisy (for a conventional type generator). It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity. I ran it out of gas and stored it away and, until just now, had forgotten I had it. It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator. :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps. It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off. I wouldn't do that on a regular basis. The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator. 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine. Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it. My 1200 watt microwave draws just over 16 amps to run. 120v x 16 amps = 1920 watts which is over the continuous output rating of the Honda (1600 watts). It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max. They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp" or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel. More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyers ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps). So why do the 15 amp receptacles say "15 amps" on them? Why is the 15 amp circuit fed from a 15 amp breaker? If code says "max on a 15a circuit is 12 amps" why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power. Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was. Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor. The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department. He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time. He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not. All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. |
#123
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Sat, 13 Oct 2018 07:46:22 -0400, "Mr. Luddite"
wrote: On 10/13/2018 5:15 AM, Mr. Luddite wrote: On 10/12/2018 10:25 PM, wrote: On Fri, 12 Oct 2018 19:03:59 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:07 PM, wrote: On Fri, 12 Oct 2018 14:34:56 -0400, "Mr. Luddite" wrote: On 10/12/2018 1:10 PM, wrote: On Fri, 12 Oct 2018 08:00:23 -0400, "Mr. Luddite" wrote: On 10/12/2018 1:04 AM, Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year.Â* It was brand new, still in the box and she decided to have a whole house generator installed instead.Â* She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300.Â* It's rated at 4,750 peak watts and 3800 watts continuous.Â* Engine is 6.3 hp. I put it together last spring and fired it up.Â* Ran fine, was not overly noisy (for a conventional type generator).Â* It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity.Â* I ran it out of gas and stored it away and, until just now, had forgotten I had it.Â* It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis.Â* Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator.Â* :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps.Â* It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off.Â* I wouldn't do that on a regular basis.Â* The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator.Â* 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine.Â* Never ran it for a long time, mostly heat water for coffee. The Honda 2000 runs the smaller, counter-top microwave fine as well, but it's only rated at 750 watts versus the 1200 watts that the over stove, built in microwave is rated at.Â*Â* I purposely shopped for the lowest wattage small microwave I could find and 750 watts seemed to be the smallest.Â* It still draws about 11 amps when running, so it needs 1320 watts of power to produce 750 watts of microwave power.Â* 1320 watts is within the Honda's rated continuous output of 1600 watts. That's the thing. Can't confuse output power rating of the microwave with the input required to produce it.Â* The large microwave was drawing slightly over 16 amps to produce 1200 watts of microwave power. That's at least 1920 watts.Â* The Honda is only rated for 1600 watts continuous output and 2000 watts "surge".Â* So to run the large microwave the Honda was running near or at it's surge rating continuously.Â* Not good. That should have a 5-20 plug on it if it pulls 16a. I assume it is on a dedicated 20a circuit. It *is* on a dedicated 20a kitchen circuit although I was wrong about it's microwave output power.Â* It's 1000 watts, not 1200 as I had previously thought. As mentioned in another post the sticker indicates a service requirement of 120vac at 1.64 Kw.Â* Output is listed as 1000 watts.Â* So, it draws 13.666 amps running ... I measured 14 amps on house power, 16 amps (briefly) on Honda power. So, on house power:Â* 1640 watts in, 1000 watts out.Â* Makes sense to me. 640w of waste heat coming out the vent sounds high to me. The vent on mine is barely warm. I had more waste heat coming out of my satellite receiver. What makes you think the extra 640 watts is "waste heat"? Any energy that is not going to the load (food in this case) is waste. You have to assume the radiated power *mostly* ends up in the food so anything else is waste. The first thing you need to know when you are computing the HVAC load (heat) in a computer room is the power coming in. (AKA sensible heat) It is roughly 3400 BTU per KH and you assume all electricity coming in goes out as heat so you are saying your microwave is pumping 2217.89 BTU in the air the whole time it is running ... plus what it does heating the food? Sorry I was an Installation Planning Rep too ;-) I really think if all of that was true you could cook another hot dog on the fan. Well Greg, the specs on the sticker didn't lie.Â* Input power required is 120vac, 1.64 Kw.Â* Output: 1Kw.Â* Confirmed by current reading of 14 amps when the microwave is running. I'll do another test.Â* I'll run it again monitoring the current but set the microwave power to 50 percent or so.Â* All that does is cycle the magnetron on and off for a 50 percent duty cycle.Â* I'll see what the current draw is when the magnetron is in it's "off" cycle. Ok. Did the above described "test". With the magnetron running the current draw is about 14 amps (bounces from about 13.8 to 14.1) When the magnetron shuts off but the microwave is still running the current drops to about 0.8 - 1.0 amperes. The fan, turntable, internal light and control/display are still running. So, when the fan, turntable, light and control/display are on, the microwave is consuming about 108 watts (0.9a * 120v) of the 1640 watts service rating. The magnetron, when it kicks in, is using an additional 13 amps or about 1560 watts. 108 watts plus 1560 watts = 1668 watts. Damn close to the service rating of 1640 watts. I attribute the 28 watt discrepancy to the accuracy of the Kill-a-Watt meter and the number I noted as it ran. The current readings tend to bounce around a bit. Each of the powered devices (the turntable motor, fan, light, controls/display and magnetron) are not 100 percent efficient obviously so there are losses in each that are given off in heat but the numbers are pretty close to the sticker reading. Obviously, the losses don't add up to 640 watts of "waste heat" going out the vent, so that's why you can't cook a hot dog on it. Thus ends my science experiment for the month. :-) All 1668 watts end up being heat eventually. The only question is how much ends up in the food. |
#124
![]()
posted to rec.boats
|
|||
|
|||
![]()
On 10/13/2018 12:18 PM, wrote:
On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg Pardon my ignorance but doesn't "cord and plug" mean an extension cord or the cord connected to the device you plug into the receptacle (like a toaster)? If so, it sorta makes sense. Tip off is that the 12 amps applies to both 15 amp and 20 amp branch circuits. If I understand it correctly, a single, dedicated 20 amp outlet with breaker and wire size (12 ga) can power a plugged in device that draws up to 20 amps but if that 20 amp branch circuit has two 20 amp outlets or more you are not suppose to plug in anything that draws more than 12 amps. If this is correct (probably isn't) who the hell enforces this? |
#125
![]()
posted to rec.boats
|
|||
|
|||
![]()
On 10/13/18 12:18 PM, wrote:
On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year. It was brand new, still in the box and she decided to have a whole house generator installed instead. She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300. It's rated at 4,750 peak watts and 3800 watts continuous. Engine is 6.3 hp. I put it together last spring and fired it up. Ran fine, was not overly noisy (for a conventional type generator). It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity. I ran it out of gas and stored it away and, until just now, had forgotten I had it. It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator. :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps. It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off. I wouldn't do that on a regular basis. The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator. 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine. Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it. My 1200 watt microwave draws just over 16 amps to run. 120v x 16 amps = 1920 watts which is over the continuous output rating of the Honda (1600 watts). It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max. They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp" or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel. More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyers ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps). So why do the 15 amp receptacles say "15 amps" on them? Why is the 15 amp circuit fed from a 15 amp breaker? If code says "max on a 15a circuit is 12 amps" why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power. Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was. Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor. The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department. He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time. He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not. All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. Damn! So, when the maids wash the floor and use my portable fans to help it dry faster, I should insist they first make sure all the fan motors are synchronized, right? Might you recommend a brand and model of synchronizer? ![]() |
#126
![]()
posted to rec.boats
|
|||
|
|||
![]()
On 10/13/2018 12:18 PM, wrote:
On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year. It was brand new, still in the box and she decided to have a whole house generator installed instead. She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300. It's rated at 4,750 peak watts and 3800 watts continuous. Engine is 6.3 hp. I put it together last spring and fired it up. Ran fine, was not overly noisy (for a conventional type generator). It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity. I ran it out of gas and stored it away and, until just now, had forgotten I had it. It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator. :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps. It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off. I wouldn't do that on a regular basis. The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator. 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine. Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it. My 1200 watt microwave draws just over 16 amps to run. 120v x 16 amps = 1920 watts which is over the continuous output rating of the Honda (1600 watts). It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max. They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp" or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel. More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyers ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps). So why do the 15 amp receptacles say "15 amps" on them? Why is the 15 amp circuit fed from a 15 amp breaker? If code says "max on a 15a circuit is 12 amps" why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power. Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was. Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor. The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department. He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time. He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not. All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. I always did it in accordance with exception 3. The PE I hired said no. But then you get into what states his license was valid etc. Either way, it worked. |
#127
![]()
posted to rec.boats
|
|||
|
|||
![]()
On 10/13/2018 1:12 PM, Keyser Soze wrote:
On 10/13/18 12:18 PM, wrote: On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year.Â* It was brand new, still in the box and she decided to have a whole house generator installed instead.Â* She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300.Â* It's rated at 4,750 peak watts and 3800 watts continuous.Â* Engine is 6.3 hp. I put it together last spring and fired it up.Â* Ran fine, was not overly noisy (for a conventional type generator).Â* It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity.Â* I ran it out of gas and stored it away and, until just now, had forgotten I had it.Â* It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator.Â* :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps.Â* It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off.Â* I wouldn't do that on a regular basis.Â* The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator.Â* 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine.Â* Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it.Â* My 1200 watt microwave draws just over 16 amps to run.Â* 120v x 16 amps = 1920 wattsÂ* which is over the continuous output rating of the Honda (1600 watts).Â* It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max.Â*Â* They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp"Â* or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel.Â* More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyersÂ* ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps).Â*Â* So why do the 15 amp receptacles say "15 amps" on them?Â*Â* Why is the 15 amp circuit fed from a 15 amp breaker?Â* If code says "max on a 15a circuit is 12 amps"Â* why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book.Â* :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power.Â* Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was.Â* Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor.Â* The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department.Â* He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time.Â* He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not.Â*Â* All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. Damn! So, when the maids wash the floor and use my portable fans to help it dry faster, I should insist they first make sure all the fan motors are synchronized, right? Might you recommend a brand and model of synchronizer?Â* ![]() ??? I assume that was an attempt at humor. |
#128
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Sat, 13 Oct 2018 12:36:57 -0400, "Mr. Luddite"
wrote: On 10/13/2018 12:18 PM, wrote: On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg Pardon my ignorance but doesn't "cord and plug" mean an extension cord or the cord connected to the device you plug into the receptacle (like a toaster)? If so, it sorta makes sense. Tip off is that the 12 amps applies to both 15 amp and 20 amp branch circuits. If I understand it correctly, a single, dedicated 20 amp outlet with breaker and wire size (12 ga) can power a plugged in device that draws up to 20 amps but if that 20 amp branch circuit has two 20 amp outlets or more you are not suppose to plug in anything that draws more than 12 amps. That is the maximum allowed per piece of equipment. If you have a dedicated 20a circuit that piece of equipment will be max 16a. If this is correct (probably isn't) who the hell enforces this? It is enforced by 240.4(D) that mandates the 14ga=15a, 12ga=20a by the allowable breaker size. If you plug in too much, you trip the breaker. If you ran the Neher McGrath formula you would find 14 ga wire really handles 20a and 12 ga handles 25a (310.16 used to say that but they changed it because Canada did) 240.4(D) was put there too ensure you still had your 80% safety margin when you turned the user loose. http://gfretwell.com/electrical/Nehe...%20formula.jpg They still enforce an additional 80% factor on each piece of equipment, making 15=12 |
#129
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Sat, 13 Oct 2018 13:12:59 -0400, Keyser Soze
wrote: On 10/13/18 12:18 PM, wrote: On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year. It was brand new, still in the box and she decided to have a whole house generator installed instead. She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300. It's rated at 4,750 peak watts and 3800 watts continuous. Engine is 6.3 hp. I put it together last spring and fired it up. Ran fine, was not overly noisy (for a conventional type generator). It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity. I ran it out of gas and stored it away and, until just now, had forgotten I had it. It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator. :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps. It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off. I wouldn't do that on a regular basis. The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator. 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine. Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it. My 1200 watt microwave draws just over 16 amps to run. 120v x 16 amps = 1920 watts which is over the continuous output rating of the Honda (1600 watts). It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max. They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp" or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel. More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyers ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps). So why do the 15 amp receptacles say "15 amps" on them? Why is the 15 amp circuit fed from a 15 amp breaker? If code says "max on a 15a circuit is 12 amps" why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power. Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was. Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor. The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department. He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time. He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not. All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. Damn! So, when the maids wash the floor and use my portable fans to help it dry faster, I should insist they first make sure all the fan motors are synchronized, right? Might you recommend a brand and model of synchronizer? ![]() Don't worry Harry. PEPCO makes sure your fan motors, or any other induction motor is sync'ed because they run at a multiple of the line frequency minus the slip. The air they move becomes an excellent rectifier tho so the air going across the floor is DC. |
#130
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Sat, 13 Oct 2018 15:07:53 -0400, "Mr. Luddite"
wrote: On 10/13/2018 12:18 PM, wrote: On Sat, 13 Oct 2018 05:31:57 -0400, "Mr. Luddite" wrote: On 10/12/2018 10:36 PM, wrote: On Fri, 12 Oct 2018 19:10:14 -0400, "Mr. Luddite" wrote: On 10/12/2018 3:57 PM, wrote: On Fri, 12 Oct 2018 14:56:36 -0400, "Mr. Luddite" wrote: On 10/12/2018 2:04 PM, wrote: On Fri, 12 Oct 2018 14:37:24 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/12/2018 5:49 AM, John H. wrote: On Fri, 12 Oct 2018 05:04:47 -0000 (UTC), Bill wrote: Mr. Luddite wrote: On 10/11/2018 8:12 PM, wrote: On Thu, 11 Oct 2018 16:42:41 -0400, "Mr. Luddite" wrote: On 10/11/2018 3:40 PM, wrote: On Thu, 11 Oct 2018 14:11:23 -0400, John H. wrote: http://tinyurl.com/y7dezaq3 "The left is revving up attacks on capitalism just as workers on the bottom rungs are beginning to benefit from the booming U.S. economy. According to last week's jobs report, unemployment has been pushed back to its lowest level since 1969. Wages in blue-collar industries, such as construction and maintenance, are rising faster than for white-collar workers. Pay for people without a college education jumped almost 6 percent since last year -- triple the overall wage gain." Gosh, I thought wage growth was stagnant. There was an article in USA Today yesterday talking about .how wages are going up across the board and some jobs are really taking off BTW your link took me to Harbor Fright generators. About that, why is my 5.5 KW Briggs 11 hp and theirs is 8? They must have stronger horses in China With no losses considered: 8 hp = 5.96Kw 11 hp = 8.2Kw I completely forgot about a small generator I bought from a neighbor last year. It was brand new, still in the box and she decided to have a whole house generator installed instead. She only wanted $200 for it but after looking it up I decided I'd be ripping her off, so I gave her $300. It's rated at 4,750 peak watts and 3800 watts continuous. Engine is 6.3 hp. I put it together last spring and fired it up. Ran fine, was not overly noisy (for a conventional type generator). It has electric start which is nice and will run on gas or propane, although propane is at a reduced output capacity. I ran it out of gas and stored it away and, until just now, had forgotten I had it. It's a "Wren" that she got from Home Depot: https://tinyurl.com/ybef4hty I keep hearing about the reduced output capacity on propane but I don't see it. I will say fuel consumption is where the difference of energy density shows up. At full load the gasoline consumption is around 0.5 GPH and propane is more like 0.8 GPH although the gasoline is easier to measure accurately. I am just going on a gauge on a 150 gallon tank and that is not very precise. After a similar discussion on the real boat group I tested my generator using my convection oven as the load. This is 5402.7w running a 5500w generator on propane http://gfretwell.com/Propaneproject/Onpropane.jpg When I plugged in two 100w lights, it tripped the breaker before I could take pictures. I think any generator can temporarily exceed their rated capacity but they may not last long if done on a regular basis. Windings and other components will get hot and go "poof". It's not often that generators are running all the time at full capacity and if they are, you probably need a bigger generator. :-) I mentioned before that the little Honda I have is rated for 2,000 watts surge and 1600 watts continuous or 13.3 amps. It ran my large microwave with a measured amperage draw of over 16 amps for a short time but as soon as I realized how much current was being drawn I shut the microwave off. I wouldn't do that on a regular basis. The circuit breaker on the generator never tripped. I've been looking around for a larger portable generator but I want one with 4 poles instead of the typical 2 poles. 4 poles will allow the engine to run at 1800 RPM to produce it's rated output at 60Hz instead of the typical 3600 RPM in a 2 pole generator. 3600 RPM is the main reason they are so noisy. My Yamaha 2000 runs my Samsung camper microwave fine. Never ran it for a long time, mostly heat water for coffee. Even the bigger microwaves are only about 1200 watts. Shouldn't be a problem for the 2000 watter. John, the 1200 watt rating is the microwave output power, not the power required to produce it. My 1200 watt microwave draws just over 16 amps to run. 120v x 16 amps = 1920 watts which is over the continuous output rating of the Honda (1600 watts). It means the Honda has to run near or at it's "surge" capacity continuously in order to power the 1200 watt microwave. I would figure most microwave units should be about 14 amps max. They are designed to run on 15 amp circuits. Max on a 15a circuit is 12a (1440w). There are a few exceptions but none if it has a plug on it. I am not a code expert but why then, when you go to Lowe's or Home Depot are the wall receptacles marked as "15 amp" or "20 amp"? I've always wired a 20 amp outlet with 12 ga romex and 15 amp with 14 ga. and use the appropriate breaker in the service panel. More often than not I skip the 15 amp altogether and just wire for 20 amp. Have the codes changed? No. A 20a has to be on 12ga but you can put a 15 on either as long as there is more than one receptacle on the circuit. A duplex is 2. There is no limit to how many you put on a circuit tho in residential. Commercial has a 180va per duplex (90 per receptacle) rating for each based on full circuit ampacity (not the 80%). I think Canada extends that to residential. The thinking in residential is receptacles are placed for convenience, not actual load and most will not be used most of the time so you can have all you want on a circuit. The NEC does not address "design". Basically they are trying to avoid the need of extension cords and cords running across doorways so the general rule is you are always within 6' of a receptacle without crossing an opening. That includes any wall space 24" or wider. In the kitchen, on the counter top you are 2' from a receptacle. This takes about 6-7 pages of fine print and pictures in the NEC to describe. Damn lawyers ;-) 210.52 is one of the more confusing articles. I understand all the convenience stuff but you said that "Max on a 15a circuit is 12amps). So why do the 15 amp receptacles say "15 amps" on them? Why is the 15 amp circuit fed from a 15 amp breaker? If code says "max on a 15a circuit is 12 amps" why aren't the breakers 12 amps and the receptacles labeled "12 amps" ? That is per plug (or piece of fixed in place equipment) There are a lot of things going on here. The rated amperes on a device (receptacle switch etc) is what it can handle without burning up (per the NRTL ; like U/L) The ampacity of a conductor is what it an handle without burning up. (and remain in a safe condition) You dealt with labs, You know that stuff. Then there is the code that tries to build an 80% safety margin into everything. 15 becomes 12 and 20 becomes 16. That is really only applicable to continuous loads (3 hours) but they always err on the safe side. If you can plug it in, they assume you need all help you can get so the NRTL puts the 1440w limit on a NEMA 5-15 plug and 1920w on a 5-20. Ah, I think you are referring to industrial code requirements. Not sure they all apply to residential wiring in a house but again, I am not an electrician and don't even have a current code book. :-) Nope 210.21(B)(2) applies to everyone (2) Total Cord-and-Plug-Connected Load. Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle shall not supply a total cord and- plug-connected load in excess of the maximum specified in Table 210.21(B)(2) http://gfretwell.com/electrical/Tabl...21%20B%202.jpg The equipment I used to build had many three phase motors and other relatively high powered components most of which ran on three phase power. Most were 480v, delta and occasionally 208 wye, depending on what the customer's service was. Typical service requirements for the average system was 60-80 KVA I used to spec the service requirements for the whole system so the customer could plan for it' installation. When I first started doing this and being knowledgeable of which motors, etc. would be on and which would be off during the system's operation, I specified the the service for the maximum KVA it could draw at any time with a safety factor. The systems never had *all* the high power consuming components running at the same time. Later, as the company grew, more people were hired and my role became more corporate management versus technical I hired an electrical engineer with a P.E. to manage the electrical department. He changed the way the systems were spec'd to include *all* the motors, etc. even though they would never run together at the same time. He said the way I had been doing it was ok ... safe ... but the code required the total of all, running or not. All it did was cause the customer's service requirements to go up dramatically but needlessly. If the motors are not electrically interlocked so they can't run together you need to compute the load based on the largest one at 125% and the rest at 100% of the full load amps 430.24 Several Motors or a Motor(s) and Other Load(s). Conductors supplying several motors, or a motor( s) and other load(s), shall have an ampacity not less than the sum of each of the following: (1) 125 percent of the full-load current rating of the highest rated motor, as determined by 430.6(A) (2) Sum of the full-load current ratings of all the other motors in the group, as determined by 430.6(A) (3) 100 percent of the noncontinuous non-motor load (4) 125 percent of the continuous non-motor load. Informational Note: See Informative Annex D, Example No. D8. Exception No.1: Where one or more of the motors of the group are used for short-time, intermittent, periodic, or varying duty, the ampere rating of such ~motors to be used in the summation shall be determined in accordance with 430. 22(E). For the highest rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous duty motor full-load current multiplied by 1.25 shall be used in the summation. Exception No.2: The ampacity of conductors supplying motor-operated fixed electric space-heating equipment shall comply with 424.3(B). Exception No.3: Where the circuitry is interlocked so as to prevent simultaneous operation of selected motors or other loads, the conductor ampacity shall be permitted to be based on the summation of the currents of the motors and other loads to be operated simultaneously that results in the highest total current. I always did it in accordance with exception 3. The PE I hired said no. But then you get into what states his license was valid etc. Either way, it worked. If they were in fact interlocked, either directly or by software design, your engineer was being overly cautious. Did you have this listed and what did U/L (or any other NRTL) say about it? If they allowed the name plate value you originally used, that is all the inspector needs to see. 110.3(B) Installation and Use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
US - Betsy Gals II 2018005-09 | Tall Ship Photos | |||
Betsy | Tall Ship Photos | |||
Hoods for LCD Displays | Cruising | |||
Hoods for LCD Displays | Electronics | |||
Hoods for LCD Displays | Cruising |