I've picked up a lot of good info reading this group , and now am in need of hopefully some info
from someone here. I have an older Onan generator Model 3MTK-1R-1G that i'm in need of wiring diagram and sevvice manual. Onan has been no help as they keep referring me to the local distributer where all you get is voice mail and never a return call. Generator Service Company was able to let me know that it was made in May of 1963. The unit turns over by using the start switch but I'm not getting voltage to the coils , so no spark at the plugs. If anyone has books on this that they would like to Sell, give away , or copy, I'd be thankfull .. Take care and good boating Rick |
#2
![]() |
|||
|
|||
![]() wrote in message ... I have an older Onan generator Model 3MTK-1R-1G that i'm in need of wiring diagram and sevvice manual. If you Onan is like mine, the wiring diagram is printed on the inside of the control box lid. This should be obvious, but did you check the fuses? Mine has three fuses: if the main fuse is blown the unit won't even crank. There is another fuse for the choke heater, and the third fuse is part of the fuel pump and I believe ignition circuit. You should also check the over temperature and oil pressure shut down switches, although I believe that if these were bad the motor would start but would stop as soon as you let go of the starter switch. Rod McInnis |
#3
![]() |
|||
|
|||
![]() |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Generator Overheating Question | General |